Soil lateral loads labc 1610 1 general.
City of los angeles standard retaining wall detail.
Concrete block retaining wall h 6 0 max b3761 1 b3761 2.
City of los angeles electrical plan check correction list.
Residential code section r404 4 specifies that retaining walls shall be designed to ensure.
Lap all steel 16.
Design of retaining walls as presented in this bulletin are in accordance with sections 1610 1 and 1807 2 of the city of los angeles building code labc.
6 concrete block masonry wall detail 6 0 height maximum general specifications.
Acceptable engineering criteria for retaining wall design.
Each series contains several standard plans.
Concrete block units shall conform to astm c90.
Retaining or slough wall 4 foot high or less 178 kb view.
City of los angeles electrical plan check correction list.
The standard plans are divided into several series.
Concrete mix for footing to be 1 part cement to 2 5 parts sand to 3 5 parts gravel with a maximum of 7 5 gallons of water per sack of cement minimum f c 2 500 psi.
Concrete block units to be staggered running bond.
Build safe well and fast with the city of los angeles department of building and safety.
San diego municipal code chapter 14 article 2.
213 847 0700.
The height of a retaining wall is measured from grade on the lower side of the retaining wall to the top of the retaining wall exposed height e sdmc 113 0270 b 2.
As a covered entity under title ii of the americans with disabilities act the city of los angeles does not discriminate on the basis of disability and upon request will provide reasonable accommodation to ensure equal access to its programs services and activities.
County of los angeles department of public works building and safety division based on the 2011 lacrc 1014 r404 4 article 1 10 25 12 page 1 of 7 design of retaining walls issue.
Informational page for pre approved standard plans.
Retaining walls heights are also regulated by the zoning laws of the city as follows.
If any information on any of the standard plans is not legible it is the user s responsibility to obtain a legible copy from the bureau of engineering vault located at.
Plumbing plan check correction list for 2017 codes 422 kb view.
Disabled access standard details notes for commercial buildings.
Multiple cover details for sanitary sewer manholes.
Reinforcing steel shall be deformed steel conforming to a s t m.
Concrete block units to have vertical continuity of the cells unobstructed.
Metal bin type retaining wall.
1149 s broadway suite b 10 los angeles ca 90015 phone.
Concrete block units to be standard 8 x8 x16 units conforming to ubc standard 21 4.